You may also like
Panamax MX5102
Combines Power Management, Surge Protection with AVM and Battery backup to provide the Complete Solution.
Panamax's MX5102 is specially designed and engineered for home theater systems. In addition to power management the battery backup prevents processor controlled devices and hard-drive based sources from losing critical data and set up configurations, as well as allowing for a proper shut down procedure.
Battery Backup
MX5102 prevents critical equipment from losing setup configuration, stored data and hard-disk crashes. Shuts off projection equipment via IR control to allow the projector bulbs to go through a proper cool-down cycle before shutting off.
Improves Picture and Sound Quality
Level 3 Power Cleaning and Linear Filtration eliminates common symptoms of contaminated power (including loss of detail, pops, hisses, hums and visual artifacts) and allows your A/V equipment to perform up to its full capability.
Reduces Cross-Contamination Between Components
The MX5102 is designed to provide noise isolation between four isolated outlet banks including 2 high current, and 2 battery backup outlets so that any noise created by an A/V component can not contaminate the power going to equipment plugged into another outlet bank.
Monitors Incoming Line Voltage and Provides a Visual Indication of Power Level
Panamax's patent pending AVM circuitry continuously monitors the incoming power as displayed on the digital voltmeter. In case of an undervoltage or an overvoltage, a flashing red LED will be displayed on the front panel, and power to the connected equipment is automatically turned off for all outlets except for the battery connected outlets, if either of these conditions is detected. When voltage returns to a safe level, power to the equipment is automatically reconnected.
Panamax MX5102 Features at a Glance
Battery Backup
600VA UPS, 2 Outlets
Clean Power Level 3
Improves picture and sound quality by eliminating noise across the entire AC bandwidth. Sixty (60%) more efficient at eliminating noise than single stage linear filtration (Level 2).
4 Isolated Outlet Banks
Isolating outlet banks from one another prevents noise contamination between components.
High Current Outlets
2 outlets for equipment with high power demands (Amps/Subwoofers).
Digital Volt Meter
Monitor the voltage supplying your home theater equipment.
AVM (Automatic Voltage Monitoring)
Protects equipment against prolonged over/ under voltages by disconnecting the power and reconnecting it when safe power returns.
12 Volt Trigger
Allows source equipment to activate or deactivate the outlets on the MX5102.
Power Sequencing
Guards against blown fuses and potentially damaging speaker thump by automatically powering outlets on and off in sequence.
10 Outlets
4 Switched, 2 Battery Backup, 2 Switched High Current, 2 Always On.
Dual Learning IR Function
Panamax's Patent-Pending Learning IR Function lets you program the UPS to send standby or shut-down commands to components such as DLP ceiling projectors.
General | |
---|---|
Family | Rack Mount |
Line Voltage | 120 (Volts) |
BlueBOLT Enabled | No |
Number of Outlets | 10 |
Number of Isolated Banks | 4 |
Outlet Descriptions | All 10 outlets filtered, and surge protected. Bank 1 is always on Bank 2 is switched by front panel power button or low voltage trigger Bank 3 is high current and switched by front panel power button or low voltage trigger Bank 4 is always on and backed up by battery |
Rack Mountable | Yes |
Rack Ears Included | Yes |
Front Panel Meter(s) | LED display indicates incoming line voltage or estimated minutes of backup time |
Front Media Light(s) | No |
Control | On/Off control via front panel power button or low voltage trigger |
Compliance | cULus |
Low Voltage Trigger | 3 - 18V DC In |
AC Power Cord | 10 ft, captive |
Dimensions | 17" W x 13" D x 4" H |
Weight | 27 lbs. |
Battery Backup | |
Output Frequency | 60 Hz ± 1% |
UPS Output Capacity | 600VA, 360W @ 0.6pf |
Regulation Output Range | 120 ± 5% Simulated Sine Wave |
UPS Backup Time (Full Load) | 3 minutes |
Transfer Time | < 10ms |
AC Protection | |
AC Protection Technology | Automatic Voltage MonitoringProtect or disconnect |
Automatic Voltage Shutoff | Yes |
Under-Voltage Shutoff | 90V ± 5V |
Over-Voltage Shutoff | 150V ± 5V (fast rise)132 ± 5V (slow rise) |
Maximum Current Rating | 12 (Amps) |
Filtration | |
Filtration Technology | RFI/EMI Filtration |
Filtration Rating | 30dB min from 100kHz-2MHz50dB max @ 270kHz |
Signal Line Protection | |
Signal Line Protection | 1 LAN 1 Tel3 Cable/Satellite |
Shipping Info | |
Length | 22 (Inches) |
Width | 17.7 (Inches) |
Height | 9.4 (Inches) |
Weight | 32.7 (Lbs) |
Unit of Measure | Each |
UPC | 050616008501 |
Master Pack Qty | 28 |
Other Specifications | |
LAN Protection - Wires Protected | 8-Wires |
LAN - Jacks | RJ-45 |
LAN - Compatibility | 10/100bT |
LAN - Clamping Level | 50V |
Telco Protection - Wires Protected | 2 Wires, 1 Pair (4, 5) |
Telco - Jacks | RJ-11 |
Telco - Fuseless/Auto-Resetting | Yes |
Telco - Clamping Level | 270V |
Telco - Suppression Modes | Metallic & Longitudinal |
Coax Protection - Shielded | YesCoax - Insertion Loss |
Coax - HD 1080 i/p Ready | Yes |
Coax - Frequency Range | 0 MHz - 2.2 GHz |
Coax - Connections | Female "F", Gold Plated |
Coax - Clamping Level | 75V |
Coax - Bidirectional | Yes |