Furman M-8S
Install an M-8S in your rack, and the eight outlets in the rear panel will power up in sequence and protect all your equipment up to a 15-amp load.
Merit M-8S Power Sequencer is the perfect low-cost AC power solution for any rack mount system where power sequencing is desired.
Install an M-8s in to the top slot of your rack, and the six delayed outlets in the rear panel will power up sequentially and protect all your equipment up to a 15-amp load.
Includes 3 delayed outlet banks - each with 2 outlets - plus 2 unswitched outlets.
Furman M-8S Features at a Glance
Power Sequencing
- Prevents excessive inrush currents.
- Six sequenced rear panel outlets (in three groups), two unswitched rear panel outlets, and one front panel unswitched outlet.
- Momentary and maintained sequencing via rear panel terminal block or front panel switch (momentary only).
Noise Filtration
Noise filtering to reduce radio frequency and electromagnetic interference.
Surge Protection
Ensures equipment stays safe.
9 Total Outlets
Eight rear panel outlets and one front panel convenience panel outlet.
15 Amp Rating
15 amp rating, with circuit breaker.
"Protection OK" Indicator
Front panel indicator LEDs for Outlet Banks, Protection OK and Power Status.
Wall Wart Spacing
Rear outlets have been spaced to accommodate even the bulkiest of wall warts and adapters.
All settings and configurations available on rear panel.
General | |
---|---|
Line Voltage | 120 (Volts) |
BlueBOLT Enabled | No |
AC Protection | |
Automatic Voltage Shutoff | No |
Shipping Info | |
Length | 21.9 (Inches) |
Width | 9.4 (Inches) |
Height | 3.4 (Inches) |
Weight | 7.65 (Lbs) |
Unit of Measure | Each |
UPC | 654061041078 |
Master Pack Qty | 6 |
Other Specifications | |
Maximum AC Current Rating | 15 Amps, 120 VAC (Thermal breaker) |
AC Cord | 14AWGx3, 10 feet, black, fixed, NEMA 5-15P plug |
Convenience Outlet (Front Panel) | 1 Un-switched NEMA 15-5R |
Rear Panel Outlets | 2 Un-switched NEMA 5-15R (1 duplex) 6 Sequenced NEMA 5-15R (3 duplexes, each controlled by separate relay) |
AC Surge Protection | Merit Class (sacrificial) |
Spike Protection Mode | Line to neutral, zero ground leakage |
Max Continuous Operating Voltage | 130V RMS |
Max Clamp Voltage | 500 Volts Peak |
Peak Impulse Current | 12,000 Amps |
Energy Rating (2 X 820µS) | 225 Joules |
AC Filtering | Pi LCR Filter |
Noise Attenuation | >26dB, 100 Khz to 1 MHz |
Operating Temperature Range | 5C (40F) to 40C (105F) degrees |
Humidity Range | <90% rH (Relative Humidity) |
Rocker Switch | Front panel, Sequence (ON, OFF) |
Thermal Circuit Breaker | Front panel, push to reset |
Front panel indicators | Delay 1, Delay 2, Delay 3, Power, Protection OK |
Control/Status/Triggering (Rear Panel) | Rear Panel DIP Switches: 12V Mode On/Off, GND Mode On, Momentary/Maintained |
Potentiometer | Rear panel, time calibration fine tune delay adjust |
Remote Terminal | +5-30VDC In, 12VDC (12mA) Out |
Remote Terminal | Phoenix type 4-Pin Connector with Screw terminals; +12V, STAT, REM, GND (Class 2 Wiring) |
Size | 1.75" X 19.00" X 6.5" (HWD) – ANSI 1RU |
Mass | 5.3 lbs. |
Power Consumption (No Load) | 5 Watts |
Safety Agency | C/CSA/US |