The M4320-PRO features Panamax™ revolutionary AVM (Automatic Voltage Monitoring) circuit, and our exclusive Linear Filtering Technology (LiFT). Together, these technologies comprise precisely what our customers have come to expect from Panamax: uncompromised AC protection and purification. Outlets: all rear panel outlets are separately controlled. They are grouped into four (4) filter-isolated banks. BlueBOLT™ is included, providing secure, hosted IP system control and monitoring for the M4320-PRO.
Panamax M4320-PRO Features at a Glance
- 20 Amp Capacity M4320-PRO
- 8 Individually Controllable Rear Panel Outlets
- Fully Programmable
- TCP/IP (BlueBOLT™) Installed
- RS-232 Card (Included, not installed)
- Linear Filtration with 3 Isolated LiFT Filter Banks, 76db (5 kHz - 250 kHz), 46 db (250 kHz - 1 MHz)
- One Isolated Filter Bank for High Current Devices, 60db (5 kHz - 450 kHz), 46 db (450 kHz - 1 MHz)
- Front Panel Circuit Breaker
- Removable Front Rack Ears
- 12 Volt Input Triggering
- Detachable 10 ft. Power Cord - 20A plug
- AVM & Protect-or-Disconnect Circuitry
General | |
---|---|
Family | Pro Series |
Line Voltage | 120 (Volts) |
BlueBOLT Enabled | Yes |
Power Factor Technology | No |
Number of Outlets | 9 |
Number of Isolated Banks | 4 |
Outlet Descriptions | 1 (always on, linearly filtered outlet, front panel) 6 (individually switchable, linearly filtered outlets) 2 (individually switchable, high current outlets) |
Rack Mountable | Yes |
Rack Ears Included | Yes |
Front Panel Meter(s) | Volts/Amps Combo Meter |
Front Media Light(s) | No |
Control | Full outlet control using BlueBOLT or Telnet commands. Limited outlet control through front panel buttons or rear panel DC trigger. |
Voltage Regulation | No |
Compliance | cCSAus |
USB Charging | N/A |
Low Voltage Trigger | 12V In |
AC Power Cord | 10 ft. detachable cord with 20 amp plug |
Dimensions | 19" W (17" without rack ears) x 12.25" D x 1.75" H |
Weight | 12 lbs |
AC Protection | |
AC Protection Technology | Protect or DisconnectAutomatic Voltage MonitoringL-N, L-G, N-G Protection ModesThermal Fusing |
Automatic Voltage Shutoff | Yes |
Under-Voltage Shutoff | 100 VAC ± 2 VAC |
Over-Voltage Shutoff | 134 VAC ± 2 VAC |
Maximum Current Rating | 20 (Amps) |
Initial Clamping Level | 200V Peak |
Filtration | |
Filtration Technology | LiFT |
Filtration Rating | Banks 1, 2, 3: 76db, 5KHz - 250 kHz Bank 4 High Current Outlets: 46 db, 250 KHz - 1 Mhz |
Signal Line Protection | |
Signal Line Protection | 1 LAN 1 Tel2 Cable/Satellite |
Shipping Info | |
Length | 19.6 (Inches) |
Width | 4.9 (Inches) |
Height | 21.4 (Inches) |
Weight | 17.55 (Lbs) |
Unit of Measure | Each |
UPC | 050616008600 |
Master Pack Qty | 2 |
Other Specifications | |
Voltage Protection Rating (UL 1449 3rd Edition, 3,000A) | 500V |
Single Pulse Energy Dissipation | 2700 Joules |
Peak Impulse Current | 135,000 Amps |
LAN - Wires Protected | 8-Wires |
LAN - Compatibility | 10/100/1000 BASE-T |
LAN - Clamping Level | 60 ± 5V |
Coax - Shielded | Yes |
Coax - Insertion Loss | < 0.5 dB |
Coax - HD 1080 i/p Ready | Yes |
Coax - Frequency Range | 0 MHz - 2.2 GHz |
Coax - Connections | Female "F", Gold Plated |
Coax - Clamping Level | 75V |
Coax - Bidirectional | Yes |